XLPE Insulated, PVC Sheathed, Individual & Overall Screened, Armoured Instrumentation Cables (Mul
日期:2018-03-15 11:24:32
点击:81
好评:0
RE-2X(St)YSWAY-TiMF 70C / 300 V APPLICATION: EN 50228-7 cables are used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not al...
XLPE Insulated, PVC Sheathed, Overall Screened & Armoured Instrumentation Cables (Multitriple)
日期:2018-03-15 11:23:50
点击:129
好评:0
RE-2X(St)YSWAY 70C / 300 V APPLICATION: En 50228-7 cables are used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed...
XLPE Insulated, PVC Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)
日期:2018-03-15 11:21:57
点击:158
好评:0
XLPE Insulated, PVC Sheathed, Overall Screened Armoured Instrumentation Cables (Single Triple) RE-2X(St)YSWAY 70C / 300 V APPLICATION: En 50228-7cables used for transmission of analogue and digital signals in instrument and control systems;...
XLPE Insulated, PVC Sheathed, Individual & Overall Screened Instrumentation Cables (Multitriple)
日期:2018-03-15 11:20:47
点击:147
好评:0
RE-2X(St)Y-TiMF 90C / 300 V APPLICATION: EN 50228-7 cables are used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowe...
XLPE Insulated, PVC Sheathed & Overall Screened Instrumentation Cables (Multitriple)
日期:2018-03-15 11:19:50
点击:82
好评:0
RE-2X(St)H90C/300V APPLICATION: EN 50228-7 cables are used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for dir...
XLPE Insulated, PVC Sheathed & Overall Screened Instrumentation Cables (Single -triple)
日期:2018-03-15 11:18:46
点击:65
好评:0
RE-2X(St)Y 90C / 300 V APPLICATION: En 50228-7 cables are used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for...
XLPE Insulated, PVC sheathed, overall screened & armoured Instrumentation cables (Multicore)
日期:2018-03-15 11:17:38
点击:133
好评:0
re-2X(st)YsWaY 90c / 500V APPLICATION En 50228-7cables used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for dir...
XLPE Insulated, PVC Sheathed & Overall Screened Instrumentation Cables (Multicore)
日期:2018-03-15 11:10:56
点击:76
好评:0
RE-2X(St)Y 90C / 500V Application EN 50288-7 cables are used for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for di...
PE Insulated, LSZH Sheathed, Individual and Overall Screened & Armoured Instrumentation Cables
日期:2018-03-15 11:05:58
点击:137
好评:0
EN 50288-7 Cables APPLICATION EN 50288-7 armoured LSZH sheathed cables are generally used when the risk of mechanical damage is increased. The galvanized steel wire armour provides excellent protection. Generally, EN 50288-7 cables are used...
PE Insulated, LSZH Sheathed, Individual and Overall Screened Instrumentation Cables (Multipair)
日期:2018-03-15 11:05:06
点击:194
好评:0
EN 50288-7 Cables APPLICATION EN 50228-7 unarmoured LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas. Generally, EN 50228-7 cables are used within industrial process manufacturing plants for...